Operation CHARM: Car repair manuals for everyone.

B259B






B259B-00-FRONT RIGHT DOOR HANDLE SENSE







- When Monitored:
During a Passive Entry or Keyless Go event.

- Set Condition:
During the Passive Entry or Keyless Go event the module looks at the door handle circuits. If the sense or return circuits are open or shorted, for over two seconds, this code will set.





1. TEST FOR INTERMITTENT CONDITION
1. Using the FOBIK, turn the ignition on.
2. Using the scan tool, record and erase the DTCs.
3. With the scan tool, select: PEM, More Options and System Tests.
4. Perform the PEM Door Handle Verification Tests.
5. With the scan tool, read the DTCs.

Does the scan tool display: B259B-00-FRONT RIGHT DOOR HANDLE SENSE as active?

Yes

- Go To 2

No

- Test complete, the condition or conditions that originally set this DTC are not present at this time. Using the wiring diagrams as a guide, check all related splices and connectors for signs of water intrusion, corrosion, pushed out or bent terminals and correct pin tension.
- Perform the BODY VERIFICATION TEST. Body Verification Test.

2. (P400) RIGHT FRONT PASSIVE ENTRY HANDLE SWITCH SENSE CIRCUIT OPEN




1. Turn the ignition off.
2. Disconnect the Right Front Exterior Door Handle Switch harness connector.
3. Turn the ignition on.
4. Measure the voltage between the (P400) Right Front Passive Entry Handle Switch Sense circuit and ground.

Is the voltage above 8.0 Volts?

Yes

- Go To 3

No

- Go To 5

3. (P401) RIGHT FRONT PASSIVE ENTRY HANDLE SWITCH RETURN CIRCUIT OPEN




1. Turn the ignition off.
2. Measure the resistance between ground and the (P401) Right Front Passive Entry Handle Switch Return circuit.

Is the resistance below 5.0 Ohms?

Yes

- Replace the Right Front Exterior Door Handle (Passive Entry).
- Perform the BODY VERIFICATION TEST. Body Verification Test.

No

- Go To 4

4. (P401) RIGHT FRONT PASSIVE ENTRY HANDLE SWITCH RETURN WIRE OPEN




1. Disconnect the Passive Entry Module C1 Harness connector.
2. Measure the resistance of the (P401) Right Front Passive Entry Handle Switch Return circuit between the PEM C1 harness connector (Cavity 5 LHD/ Cavity 3 RHD) and the Right Front Exterior Door Handle harness connector.

Is the resistance below 2.0 Ohms?

Yes

- Replace the Passive Entry Module.
- Perform the BODY VERIFICATION TEST. Body Verification Test.

No

- Repair the (P401) Right Front Passive Entry Handle Switch Return wire for an open.
- Perform the BODY VERIFICATION TEST. Body Verification Test.

5. (P400) RIGHT FRONT PASSIVE ENTRY HANDLE SWITCH SENSE WIRE OPEN




1. Turn the ignition off.
2. Disconnect the Passive Entry Module C1 harness connector.
3. Measure the resistance of the (P400) Right Front Passive Entry Handle Switch Sense wire between the PEM C1 harness connector (Cavity 4 LHD/ Cavity 2 RHD) and the Right Front Passive Entry Handle Switch harness connector.

Is the resistance below 2.0 Ohms?

Yes

- Go To 6

No

- Repair the (P400) Right Front Passive Entry Handle Switch Sense wire for an open.
- Perform the BODY VERIFICATION TEST. Body Verification Test.

6. (P400) RIGHT FRONT PASSIVE ENTRY HANDLE SWITCH SENSE WIRE SHORTED TO GROUND




1. Measure the resistance between ground and the (P400) Right Front Passive Entry Handle Switch Sense wire.

Is the resistance below 20,000 Ohms?

Yes

- Repair the (P400) Right Front Passive Entry Handle Switch Sense wire for a short to ground.
- Perform the BODY VERIFICATION TEST. Body Verification Test.

No

- Go To 7

7. (P400) RIGHT FRONT PASSIVE ENTRY HANDLE SWITCH SENSE CIRCUIT SHORTED TO THE (P401) RIGHT FRONT PASSIVE ENTRY HANDLE SWITCH RETURN CIRCUIT




1. Measure the resistance between the (P400) Right Front Passive Entry Handle Switch Sense circuit and the (P401) Right Front Passive Entry Handle Switch Return circuit.

Is the resistance below 20,000 Ohms?

Yes

- Repair the (P400) Right Front Passive Entry Handle Switch Sense circuit for a short to the (P401) Right Front Passive Entry Handle Switch Return circuit.
- Perform the BODY VERIFICATION TEST. Body Verification Test.

No

- Replace the Passive Entry Module.
- Perform the BODY VERIFICATION TEST. Body Verification Test.