Idle Speed/Throttle Actuator - Electronic: Service and Repair
6-258 Engine
1. Remove air cleaner.
2. Disconnect stepper motor wire connector. Use care to avoid dropping metering pins and spring when removing motor.
3. Remove retaining screws and unit from carburetor.
4. Reverse procedure to install. Torque retaining screw to 25 inch lbs.