Oil Charge Additions
When replacing system components, add the following quantities of refrigerant oil:- Compressor - amount drained from failed unit, plus 1 ounce
- Accumulator/Drier - amount drained from failed unit, plus 1 ounce
- Condenser - 1 ounce
- Evaporator - 3 ounces