Operation CHARM: Car repair manuals for everyone.

Pulse Generator B

INSPECTION CONDITION CRITERION VALUE
D range, stopping state 0 RPM
D range, 3rd speed, 50 MPH 1600 - 2200 RPM
D range, 4th speed, 50 MPH 1600 - 2200 RPM

POSSIBLE CAUSE (OR REMEDY) FOR THE ABNORMALITY
- Defective pulse generator B or harness
- Defective shield of pulse generator B
- External noise invasion