Expansion Block/Orifice Tube: Service and Repair
EVAPORATOR CORE ORIFICESpecial Tool(s):
SPECIAL TOOL(S)
REMOVAL
1. Disconnect the fitting.
1 Remove the screw.
2 Disconnect the fitting.
- For a fixed orifice tube, carry out Steps 2 and 3.
- For a broken orifice tube, carry out Steps 4 and 5.
2. Engage the Fixed Orifice Tool to the A/C evaporator core orifice.
3. Hold the tool T-handle stationary and rotate the tool body to remove the A/C evaporator core orifice.
4. To remove a broken A/C evaporator core orifice, screw the end of the Broken Orifice Extractor into the broken A/C evaporator core orifice.
5. Hold the tool T-handle stationary and rotate the tool body to remove the broken A/C evaporator core orifice.
INSTALLATION
1. Lubricate and install the O-ring seals on the A/C evaporator core orifice in clean PAG oil.
2. Place the A/C evaporator core orifice into the Fixed Orifice Tube Tool.
3. Insert the A/C evaporator core orifice into the condenser to evaporator tube until seated.
4. Remove the Fixed Orifice Tube Tool.
5. Install the condenser to evaporator tube.