Air Cleaner
Air Cleaner
1. Disconnect the Mass Air Flow (MAF) sensor electrical connector.
2. Loosen the clamp and disconnect the Air Cleaner (ACL) outlet pipe from the ACL cover.
- To install, tighten to 3 Nm (27 lb-in).
3. Remove the 2 ACL assembly bolts.
- To install, tighten to 8 Nm (71 lb-in).
4. NOTE: No tools are required to remove the ACL assembly. Removal should be carried out using hands only.
Release the ACL assembly from the body isolator.
- Remove the ACL assembly.
5. NOTE: Make sure the ACL assembly is seated into the body isolator.
NOTE: The ACL outlet pipe should be securely sealed to prevent unmetered air from entering the engine.
To install, reverse the removal procedure.