Fuel Pump Control Unit: Service and Repair
Fuel Pump Control Module
Exploded View
Removal
1. Remove the RH (Right Hand) C-pillar trim panel REFER to C-Pillar Trim Panel - With Inflatable Safety Belts C-Pillar Trim Panel - With Inflatable Safety Belts or REFER to C-Pillar Trim Panel - Without Inflatable Safety Belts C-Pillar Trim Panel - Without Inflatable Safety Belts.
2. Disconnect the FP (Fuel Pump) control module electrical connector.
3. Remove the 2 FP (Fuel Pump) control module retaining nuts.
4. Remove the FP (Fuel Pump) control module.
Installation
1. Install the FP (Fuel Pump) control module.
2. Install the 2 FP (Fuel Pump) control module retaining nuts.
- Tighten to 6 Nm (53 lb-in).
3. Connect the FP (Fuel Pump) control module electrical connector.
4. Install the RH (Right Hand) C-pillar trim panel REFER to C-Pillar Trim Panel - With Inflatable Safety Belts C-Pillar Trim Panel - With Inflatable Safety Belts or REFER to C-Pillar Trim Panel - Without Inflatable Safety Belts C-Pillar Trim Panel - Without Inflatable Safety Belts.