JA21 - Check CKP+ Circuit For Short High - Bias High Fault
- Key Off.
- Disconnect ICM from ICM tee, leave EI diagnostic harness connected to vehicle harness connector.
- DVOM on 40 volt DC scale.
- Key On, Engine Off.
- Measure voltage between +J35 (CKP+ I) and -J7 (B-) at breakout box.
- Is DC voltage less than 0.5 volts?
YES -- REPLACE ICM. REMOVE all test equipment. RECONNECT all components. Clear continuous memory. Clearing Diagnostic Trouble Codes
Rerun quick test. Diagnostic Subroutines (DSR) - Extracting Codes
NO -- CHECK connectors, SERVICE or REPLACE harness. CKP+ is shorted high. REMOVE all test equipment. RECONNECT all components. Clear continuous memory. Clearing Diagnostic Trouble Codes
Rerun quick test. Diagnostic Subroutines (DSR) - Extracting Codes