AIR15 - Check AIRD Valve Diaphragm
^ Connect an auxiliary vacuum source to the AIRD valve.^ Apply 34 kPa (10 in Hg) vacuum and hold.
^ Does valve hold vacuum?
YES -- Go to AIRl6. AIR16 - Check For Air Supply at AIRD Valve
NO -- Replace AIRD valve. Verify drive concern.