Initial Inspection and Diagnostic Overview
1. Verify the customer concern by operating the horn.2. Visually inspect for obvious signs of mechanical and electrical damage.
VISUAL INSPECTION CHART
Mechanical
^ Damaged horns
^ Damaged horn switch
^ Damaged air bag sliding contact
Electrical
^ Blown battery junction box Fuse Horn Relay (20 A)
^ Damaged wiring harness
^ Damaged connections
^ Damaged horn relay
^ Damaged horn switch
3. If fault is not visually evident, determine the symptom and proceed to Symptom Chart. Symptom Related Diagnostic Procedures