Accumulator HVAC: Service and Repair
REMOVAL1. Perform the Refrigerant Discharging and Recovery Procedure.
2.Disconnect the A/C cycling switch connector.
3. Remove the cycling switch.
4. Disconnect the suction line.
5. Remove the clamp nut.
6. Disconnect the accumulator from the evaporator.
7. Remove the accumulator.
INSTALLATION
1 .To install, reverse the removal procedure.
- Lubricate the O-ring seal with PAG Compressor Oil, YN-12c, F7AZ-19589-DA or equivalent meeting Ford specification WSH-M1C231-B.