Compressor Fitting HVAC: Service and Repair
NOTE: Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of contamination from a failed A/C compressor or damage to the suction accumulator.REMOVAL
1. Recover the refrigerant.
2. Disconnect the suction line spring lock coupling.
- Discard the O-ring seals.
3. Remove the A/C muffler bracket nut.
4. Disconnect the spring lock coupling.
- Discard the O-ring seals.
5. Raise the vehicle.
6. Remove the bolt and the compressor manifold assembly.
- Discard the O-ring seals.
INSTALLATION
1. To install, reverse the removal procedure.
- Install new O-ring seals lubricated in clean PAG oil.
- Lubricate the refrigerant system with the correct amount of clean PAG oil.
2. Evacuate, leak test and charge the refrigerant system.