Initial Inspection and Diagnostic Overview
INSPECTION AND VERIFICATION1. Verify the customer concern.
2. Visually inspect for obvious signs of electrical damage.
VISUAL INSPECTION CHART
Electrical
- Battery junction box (BJB) fuse 22 (20A)
- Daytime running lamp (DRL) relay
- Low beam relay
- Circuitry
- Headlamp switch
3. If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the next step.
4. If the concern is not visually evident, verify the symptom and GO to Symptom Chart. Symptom Related Diagnostic Procedures