High Pressure Safety Valve HVAC: Description and Operation
A/C COMPRESSOR PRESSURE RELIEF VALVENOTE: If the A/C compressor is operating within limits and the A/C pressure relief valve is venting, or if the A/C pressure relief valve is leaking the threads, install a new A/C pressure relief valve and O-ring. If the A/C pressure relief valve still vents after it is replaced, diagnose the refrigerant system for a restriction.
An A/C compressor pressure relief valve is incorporated in the compressor manifold and tube assembly (4.0L) or the A/C compressor (4.6L or 5.4L) to prevent damage to the A/C compressor other system components, and to avoid total refrigerant loss by relieving unusually high refrigerant system discharge pressure buildups. For specifications regarding operating pressure(s), refer to Heating and Air Conditioning.