Operation CHARM: Car repair manuals for everyone.

Pinpoint Test J: The Autolock Does Not Operate Correctly




Handles, Locks, Latches and Entry Systems

Pinpoint Tests

Pinpoint Test J: The Autolock Does Not Operate Correctly

Normal Operation

The Smart Junction Box (SJB) energizes the lock relay based on input from the ajar switches, the ignition switch, the Transmission Range (TR) sensor and the vehicle speed signal. The SJB locks the doors when the following conditions are met:

- All the doors are closed
- The ignition switch is in the ON position
- The vehicle is shifted into any gear putting the vehicle in motion
- The vehicle attains a speed greater than 20 km/h (12 mph)

This pinpoint test is intended to diagnose the following:

- Wiring, terminals or connectors
- Programming
- Door ajar switches
- SJB


PINPOINT TEST J: THE AUTOLOCK DOES NOT OPERATE CORRECTLY

-------------------------------------------------
J1 VERIFY THE AUTOLOCK FEATURE IS ENABLED


- Verify the autolock feature is enabled. Refer to Autolock and Auto-Unlock Programming Autolock and Auto-Unlock Programming.
- Is the autolock feature enabled?

Yes
GO to J2.

No
PROGRAM the autolock feature. REFER to Autolock and Auto-Unlock Programming Autolock and Auto-Unlock Programming.

-------------------------------------------------
J2 CHECK THE COURTESY LAMP OPERATION


- Open and close the doors while checking the courtesy lamp operation.
- Do the courtesy lamps operate correctly?

Yes
GO to J3.

No
REFER to Interior Lighting Testing and Inspection.

-------------------------------------------------
J3 CHECK THE SJB PID (IGN_R_ECU)


- Ignition ON.
- Enter the following diagnostic mode on the scan tool: SJB DataLogger.
- Monitor the SJB PID (IGN_R_ECU).
- Does the PID indicate RUN?

Yes
GO to J4.

No
REFER to Steering Column Switches Testing and Inspection.

-------------------------------------------------
J4 RETRIEVE THE RECORDED SJB DTCs FROM THE SELF-TEST


- Check for recorded SJB DTCs from the self-test.
- Is DTC U0155 recorded?

Yes
REFER to Multifunction Electronic Modules Testing and Inspection.

No
GO to J5.

-------------------------------------------------
J5 CHECK FOR CORRECT SJB OPERATION


- Disconnect all the SJB connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?

Yes
INSTALL a new SJB. REFER to Multifunction Electronic Modules Service and Repair. TEST the system for normal operation

No
The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.

-------------------------------------------------