Principles of Operation




Engine Cooling

Principles of Operation

Engine coolant flows primarily from the engine to the radiator circuit and back to the coolant pump. Coolant is sent from the coolant pump through the engine block and cylinder heads. A separate circuit from the engine also feeds the heater core and turbochargers with coolant. The coolant pump, operated by engine rotation through a sprocket which is driven by the timing chain, circulates the coolant. The coolant thermostat is a control valve actuated by coolant temperature. When the thermostat is closed, coolant flow bypasses the radiator circuit and returns to the coolant pump. When the thermostat is opened, coolant flows through the radiator circuit to transfer engine-generated heat to the outside air.

NOTE: The vehicle is equipped with an expansion tank.

The coolant expansion tank holds surplus coolant, allows for coolant expansion and replenishes coolant to the cooling system. It is equipped with a non-pressurized cap which allows coolant to be added to the tank to keep it filled to prescribed levels.

The cooling fan draws air through the radiator to help cool the system coolant as it passes through the radiator.

The thermostat monitor is a function of the PCM and is designed to verify correct thermostat operation. The monitor executes once per drive cycle and has a monitor run duration of 300-800 seconds. If a malfunction occurs, DTC P0125 or P0128 is set, and the Malfunction Indicator Lamp (MIL) is illuminated.

For engine specific information, refer to Engine Cooling Description and Operation in the Description and Operation.