Operation CHARM: Car repair manuals for everyone.

Pinpoint Test Z: The LH/RH Turn Indicator Is Never/Always On




Instrumentation, Message Center and Warning Chimes

Pinpoint Tests

Pinpoint Test Z: The LH/RH Turn Indicator Is Never/Always On

Normal Operation

When the multifunction switch is in the LH or RH TURN position a message is sent to the Instrument Panel Cluster (IPC) from the Smart Junction Box (SJB) over the Medium Speed Controller Area Network (MS-CAN) communication bus. Upon receipt of the LH/RH turn message, the IPC flashes the LH or RH turn signal indicator on and off.

This pinpoint test is intended to diagnose the following:

- Turn signal concern
- SJB
- IPC

PINPOINT TEST Z: THE LH/RH TURN INDICATOR IS NEVER/ALWAYS ON

-------------------------------------------------
Z1 CHECK THE LH OR RH TURN SIGNAL LAMPS OPERATION


- Ignition ON.
- Operate the LH or RH turn signal. Observe the exterior LH or RH turn lamps.
- Do the turn signal lamps operate correctly?

Yes
GO to Z2.

No
REFER to Exterior Lighting Testing and Inspection.

-------------------------------------------------
Z2 CARRY OUT THE IPC INDICATOR LAMP CONTROL ACTIVE COMMAND USING THE SCAN TOOL


- Enter the following diagnostic mode on the scan tool: IPC DataLogger.
- Select the IPC RH or LH turn signal indicator (RH_TURN_L) or (LH_TURN_L) active command. Command the RH or LH turn signal indicator on and off while observing the LH or RH turn signal indicator.
- Does the LH or RH turn signal indicator illuminate when commanded on, and turn off when commanded off?

Yes
GO to Z3.

No
INSTALL a new IPC. REFER to Instrument Panel Cluster (IPC) Service and Repair. TEST the system for normal operation.

-------------------------------------------------
Z3 RETRIEVE THE RECORDED DTCs FROM THE IPC SELF-TEST


- Check for recorded DTCs from the IPC self-test.
- Are any DTCs recorded?

Yes
For DTC U0140:87, GO to Pinpoint Test AT. Pinpoint Test AT: DTC U0140:87

For all other DTCs, REFER to DTC Charts. Instrumentation, Message Center, and Warning Chimes

No
INSTALL a new SJB. REFER to Multifunction Electronic Modules Service and Repair. TEST the system for normal operation.

-------------------------------------------------