DTC 43
Crank Signal Circuit - No Signal:
Crank Signal Circuit:
Test Description:
Number(s) below refer to circled number(s) on the diagnostic chart.
Diagnostic Aids:
An intermittent may be caused by a poor connection, rubbed through wire insulation, or a wire broken inside the insulation. Inspect hamess connectors for backed out terminals, improper mating, broken locks, improperly formed or damaged terminals and poor terminal-to-wire connections before component replacement.