Operation CHARM: Car repair manuals for everyone.

Blower Motor: Description and Operation

CIRCUIT OPERATION
Battery voltage is applied at all times through the Heater Fusible Link to the switch contact of the Heater Relay. Ignition voltage is applied to the coil of the Heater Relay when the ignition switch is in the "ON" and "START" positions. When the Blower Speed Selector Switch is moved to any position other than "OFF," the coil of the Heater Relay is provided with a ground through the Blower Speed Selector Switch and Junction Block 2 to G204. With power and ground provided, the relay energizes, its contacts close and voltage is applied to the Blower Motor. Blower Motor speed is maintained by controlling the voltage potential to the Blower Motor. This is achieved by increasing/decreasing the resistance within the Blower Motor's ground path.

With the Blower Speed Selector Switch in "LO," current must travel through the entire resistive element in the Blower Motor Resistor before the Blower Motor's ground path is completed through the Blower Speed Selector Switch and Junction Block 2 to G204. This reduces the voltage potential to the Blower Motor greatly and in turn causes the Blower Motor to run at low speed.

When the Blower Speed Selector Switch is in the M1 position, the Blower Motor's ground path travels only partially through the resistive element in the Blower Motor Resistor before completing the ground path at G204 through the Blower Speed Selector Switch and Junction Block 2. Since less of the Blower Motor Resistor is in the circuit, the resistance in the circuit is lower, thus making the voltage potential of the circuit higher. Therefore, the Blower Motor operates at a higher speed than it does with the Blower Speed Selector Switch in the "LO" position.

M2 operation is identical to M1 operation with the exception that even less of the Blower Motor Resistor is in the circuit. Therefore, Blower Motor operation in M2 is faster than it is in both M1 and "LO."

With the Blower Speed Selector Switch in "HI," the ground path of the Blower Motor bypasses the Blower Motor Resistor entirely and passes directly through the Blower Speed Selector Switch and Junction Block 2 to G204. Therefore, the resistance in the ground path is nearly zero and the Blower Motor operates on full system voltage. Under these conditions, the Blower Motor operates at full speed.