System Specifications
ATMOSPHERIC PRESSURE (PA) SENSOR
Atmospheric pressure gauge/Sensor output voltage
0 in. Hg (0 mm Hg) 2.75-3.0 Volts
5 in. Hg (125 mm Hg) 2.25-2.5 Volts
10 in. Hg (250 mm Hg) 1.75-2.0 Volts
15 in. Hg (375 mm Hg) 1.25-1.5 Volts
20 in. Hg (500 mm Hg) 1.0-1.25 Volts
25 in. Hg (625 mm Hg) 0.5-0.75 Volts
COOLANT TEMPERATURE (TW) SENSOR
Coolant Temperature/Sensor Resistance
-4° F (-20° C) 15K Ohms
32° F (0° C) 5K Ohms
104° F (40° C) 1K Ohms
176° F (80° C) 350 Ohms
248° F (120° C) 100 Ohms
ELECTRONIC AIR CONTROL VALVE (EACV)
Coolant Temperature/Idle Speed
-4° F (-20° C) 1450 rpm
32° F (0° C) 1400 rpm
104° F (40° C) 1250 rpm
176° F (80° C) 750 rpm
INTAKE AIR TEMPERATURE (TA) SENSOR
Intake Air Temperature/Sensor Resistance
-4° F (-20° C) 15K Ohms
32° F (0° C) 5K Ohms
104° F (40° C) 1K Ohms
176° F (80° C) 350 Ohms
248° F (120° C) 100 Ohms
MANIFOLD ABSOLUTE PRESSURE SENSOR (MAP)
Manifold Absolute Pressure/Sensor output voltage
0 in. Hg (0 mm Hg) 2.75-3.0 Volts
5 in. Hg (125 mm Hg) 2.25-2.5 Volts
10 in. Hg (250 mm Hg) 1.75-2.0 Volts
15 in. Hg (375 mm Hg) 1.25-1.5 Volts
20 in. Hg (500 mm Hg) 1.0-1.25 Volts
25 in. Hg (625 mm Hg) 0.5-0.75 Volts