Variable Valve Timing Pressure Switch: Service and Repair
EOP Sensor Removal/Installation1. Remove the cowl cover and under-cowl panel.
2. Disconnect the EOP sensor connector (A).
3. Remove the bracket (B) and the EOP sensor (C).