The A/C Condenser and Radiator Fans Are Inoperative With The A/C On. The Blower and Heater Controls Work Normally (With A/C)
The A/C condenser and radiator fans are inoperative with the A/C on. The blower and heater controls work normally
Diagnostic Procedure:
1. Probable cause: Radiator/condenser fan common circuit malfunction
2. Do the radiator and A/C condenser fan common circuit troubleshooting Radiator And A/C Condenser Fan Common Circuit Troubleshooting (With A/C)
Also check for:
- HVAC DTCs How to Troubleshoot the Heating and A/C Systems (With A/C)
- Powertrain DTCs; '00-05 models, '06-09 models Initial Inspection and Diagnostic Overview
- Poor body ground at G201
- '00-05 models: Faulty radiator fan switch
- Poor or loose connections at the terminals