CKP Sensor Replacement
CKP Sensor Replacement
1. Remove the CKP sensor (A).
2. Disconnect the CKP sensor 3P connector (B).
3. Install the parts in the reverse order of removal with a new O-ring (C).
4. Do the CKP pattern clear/CKP pattern learn procedure. Initial Inspection and Diagnostic Overview