Advanced Diagnostics
Advanced Diagnostics - DTC P0523: Rocker Arm Oil Pressure Sensor (Engine Oil Pressure (EOP) Sensor) Circuit High VoltageGeneral Description
The rocker arm oil pressure sensor detects the engine oil pressure in the valve pause system. When the voltage from the rocker arm oil pressure sensor is a set value for a specified time, the powertrain control module (PCM) detects a malfunction and stores a DTC.
Monitor Execution, Sequence, Duration, DTC Type, OBD Status
Enable Conditions
Malfunction Threshold
The rocker arm oil pressure sensor output voltage is 4.79 V or more for at least 2.0 seconds.
Diagnosis Details
Conditions for setting the DTC
When a malfunction is detected, the MIL comes on and a Pending DTC, a Confirmed DTC, and the freeze data are stored in the PCM memory.
Conditions for clearing the DTC
The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the battery.