Gauge Control Module
DTC Troubleshooting: U0100
DTC U0100:
Gauge Control Module Lost Communication With ECM/PCM
NOTE: If you are troubleshooting multiple DTCs, be sure to follow the instructions in B-CAN System Diagnosis Test Mode A Troubleshooting - B-CAN System Diagnosis Test Mode A.
1. Clear the DTCs with the HDS.
2. Turn the ignition switch to LOCK (0) and then back to ON (II).
3. Wait for at least 6 seconds.
4. Check for DTCs with the HDS.
Is DTC U0100 indicated?
YES -
Go to step 5.
NO -
Intermittent failure, the system is OK at this time. Check for loose or poor connections.�
5. Check for Fuel and Emission system DTCs with the HDS.
Are any DTCs indicated?
YES -
Go to the indicated DTC's troubleshooting, then recheck.�
NO -
Go to step 6.
6. Turn the ignition switch to LOCK (0).
7. Disconnect the gauge control module 32P connector.
8. Jump the SCS line with the HDS.
9. Disconnect ECM/PCM connector A (49P).
10. Check for continuity between gauge control module 32P connector terminals No. 19 and No. 20 and ECM/PCM connector A (44P) terminals No. 36 and No. 37 individually.
Is there continuity?
YES -
Update the ECM/PCM if it does not have the latest software ECM/PCM Update, or substitute a known-good ECM/PCM, and recheck. If the indication goes away, replace the original ECM/PCM Service and Repair. If the DTC is still present, replace the gauge control module Service and Repair.�
NO -
Repair an open or high resistance in the wire.�