CMP Pulse Plate Removal/Installation
CMP Pulse Plate Removal and Installation
Removal
1. Remove the air cleaner Service and Repair.
2. Remove the intake manifold chamber.
3. Disconnect the following engine wire harness connectors, and remove the wire harness clamps from the cylinder head:
- Four injector connectors
- ECT sensor 1 connector
- CMP sensor connector
- A/F sensor connector
- Secondary HO2S connector
4. Remove the harness holder mounting bolt and the ground cable, then remove the harness holder from the bracket.
5. Remove the cylinder head cover Cylinder Head Cover Removal.
6. Remove the camshaft thrust cover (A).
7. Hold the camshaft with an open-end wrench, then loosen the bolt.
8. Remove the CMP pulse plate (A).
Installation
1. Install the CMP pulse plate (A).
2. Hold the camshaft with an open-end wrench, then tighten the bolt.
3. Install the camshaft thrust cover (A) with a new O-ring (B).
4. Install the cylinder head cover Cylinder Head Cover Installation.
5. Install the harness holder, then install the ground cable.
6. Connect the following engine wire harness connectors, and install the wire harness clamps from the cylinder head:
- Four injector connectors
- ECT sensor 1 connector
- CMP sensor connector
- A/F sensor connector
- Secondary HO2S connector
7. Install the intake manifold chamber.
8. Install the air cleaner Service and Repair.