Refrigerant Pressure Sensor / Switch: Service and Repair
AIR CONDITIONING (A/C) REFRIGERANT PRESSURE SENSOR REPLACEMENTREMOVAL PROCEDURE
1. Disconnect the electrical connector from the A/C refrigerant pressure sensor.
2. Remove the A/C refrigerant pressure sensor from the evaporator tube.
INSTALLATION PROCEDURE
NOTE: Refer to Fastener Notice in Service Precautions.
1. Install the A/C refrigerant pressure sensor.
Tighten
Tighten the switch to 6 N.m (53 lb in).
2. Connect the electrical connector to the A/C refrigerant pressure sensor.