Filler Tube and Seal Replacement

FILLER TUBE AND SEAL REPLACEMENT

REMOVAL PROCEDURE




1. Remove the transmission oil level indicator.
2. Raise the vehicle. Refer to Vehicle Lifting.
3. Remove the right hand catalytic converter.
4. Remove the transmission heat shield bolt and shield.
5. Remove the nut securing the oil lever indicator tube to the transmission housing.




6. Place a drain pan under the vehicle.
7. Remove the oil level indicator tube from the transmission case and seal.
8. Remove the seal from the transmission case.

INSTALLATION PROCEDURE




1. Install a new seal into the transmission case.
2. Install the oil level indicator tube into the seal.

NOTE: Refer to Fastener Notice in Service Precautions.




3. Install the nut securing the oil level indicator tube to the transmission stud.

Tighten
Tighten the nut to 18 N.m (13 lb ft).

4. Install the transmission heat shield.
5. Install the 2 bolts retaining the heat shield.

Tighten
Tighten the bolts to 17 N.m (13 lb ft).

6. Install the right hand catalytic converter.
7. Lower the vehicle.
8. Fill the transmission to the proper level with DEXRON(R) III transmission fluid. Refer to Transmission Fluid Checking Procedure.