A/C - Revised Recirculation Door Actuator Replacement
Bulletin No.: 06-01-39-003Date: March 31, 2006
SERVICE MANUAL UPDATE
Subject:
Revised Recirculation Actuator Replacement
Models:
2003-2006 HUMMER H2
This bulletin is being issued to revise the Recirculation Actuator Replacement procedure in the HVAC Systems-Automatic sub-section of the Service Manual. Please replace the current information in the Service Manual with the following information.
The following information has been updated within SI. If you are using a paper version of this Service Manual, please make a reference to this bulletin on the affected page.
Recirculation Actuator Replacement
Removal Procedure
1. Remove the instrument panel (I/P) upper trim pad. Refer to Trim Pad Replacement - Instrument Panel (I/P) Upper.
2. Disconnect the electrical connector from the recirculation actuator.
3. Remove the screws from the recirculation actuator (1).
4. Remove the recirculation actuator (1) from the HVAC module assembly (2).
Installation Procedure
1. Install the recirculation actuator (1) to the HVAC module assembly (2).
Note:
Refer to Fastener Notice in Cautions and Notices.
2. Install the screws to the recirculation actuator (1).
Tighten
Tighten the screws to 2 N.m (18 lb in).
3. Connect the electrical connector to the recirculation actuator.
4. Install the I/P upper trim pad. Refer to Trim Pad Replacement - Instrument Panel (I/P) Upper.
5. Reprogram the recirculation actuator. Refer to Re-Calibrating Actuators.
Disclaimer