Instrument Cluster / Carrier: Service and Repair
Instrument Cluster Replacement
Removal Procedure
Important: The ignition switch must be in the OFF position when removing the instrument panel (I/P) cluster.
1. Remove the I/P cluster trim plate from the instrument panel.
2. Remove the screws from the I/P cluster to instrument panel.
3. Remove the I/P cluster from the instrument panel.
4. Disconnect the I/P cluster electrical connections.
Installation Procedure
1. Connect the electrical connections to the cluster.
2. Position the I/P cluster to the instrument panel.
Notice: Refer to Fastener Notice.
3. Install the screws to the instrument panel cluster.
Tighten the screws to 2 N.m (18 lb in).
4. Install the instrument cluster trim plate.
When the I/P cluster is replaced the new I/P cluster will need to be programmed. Refer to Instrument Cluster Programming and Setup. Programming and Relearning