Operation CHARM: Car repair manuals for everyone.

Main Relay (Computer/Fuel System): Testing and Inspection





Circuit Diagram








Harness Inspection Procedure

Harness Inspection Procedure
1. Check continuity of relay contacts by energizing terminals 4(+) and 2(-).





Between terminals 5 and 1
When de-energized: no continuity
When energized: continuity





Between terminals 5 and 3
When de-energized: no continuity
When energized: continuity


2. If faulty, replace the MFI control relay.

Tightening torque: 7 - 11 Nm (5.2 - 8.1 ft lb)