Inspection Procedure
INSPECTION PROCEDURE
INSPECTION USING SCAN TOOL
Pulse generator A
Check Conditions/Normal Value
D range; driving at 30 km/h (19 mph) in 2nd gear / 0 rpm
D range; driving at 50 km/h (31 mph) in 3rd gear / 1400-1800 rpm
D range; driving at 50 km/h (31 mph) in 4th gear / 0 rpm
Probably Cause Or Remedy
Pulse generator A or circuit harness malfunction.
Pulse generator A shielded line malfunction.
Intrusion of external noise.
Kickdown brake slippage.
Pulse generator B
Check Conditions/Normal Value
D range; stopped / 0 rpm
D range; driving at 50 km/h (31 mph) in 4th gear / 1600-2000 rpm
Probably Cause Or Remedy
Pulse generator B or circuit harness malfunction.
Pulse generator shielded line malfunction.
Intrusion of external noise.