Knock Sensor: Testing and Inspection
CIRCUIT DIAGRAM
TROUBLESHOOTING PROCEDURES
HARNESS INSPECTION PROCEDURES
SENSOR INSPECTION
1. Disconnect the knock sensor connector
2. Measure resistance between the terminal 2 and 3.
Standard value: about 5 M Ohms [at 20°(68°F)]
3. If the resistance is continual, replace the knock sensor.
Knock sensor torque: 16 - 25 Nm (11.8 - 18.4 lb ft)