Operation CHARM: Car repair manuals for everyone.

Instrument Panel, Gauges and Warning Indicators: Testing and Inspection





CIRCUIT DIAGRAM

Seat Belt Warning





1. Time specification
T1 : 6 Sec. - 1 sec.
T2 : 6 sec. - 1 sec. MAX.
T3, T4 : 0.3 sec. - 0.1 sec.

Door Warning





1. Time specification
T1, T2 : 0.3 sec - 0.1 sec.

Central Door Lock/Unlock





1. Time specification
T1 : 0.5 - 0.1 sec.

Ignition key reminder





1. Time specification
T1, T3 : 0.5 sec.
T2: 1 sec.