Operation CHARM: Car repair manuals for everyone.

Main Relay (Computer/Fuel System): Testing and Inspection




CIRCUIT DIAGRAM







HARNESS INSPECTION PROCESSOR

MFI CONTROL RELAY INSPECTION










1. Check continuity of relay contacts between terminal 4 (+) and 2 (-).




2. If faulty, replace the MFI control relay.

Tightening torque
MFI control relay: 7-11 Nm (7-110 kg.cm, 5.2-8.1 lbf)