Alarm Module: Testing and Inspection
Check that the following components operates normally as timing chart.Intermittent Wiper
1. Time specification
T1 : 0.15 sec. MAX.
T2 : 0.7 sec. (Time of wiper motor 1 rotation)
T3 : 1.5 sec. ± 0.7 sec. (VR=0 k Ohms)
10.5 sec. ± 1 sec. (VR=50 k Ohms)
Wiper Motor Related to Washer S/W
1. Time specification
T1 : 0.5 sec.
T2 : 2.5 - 3.8 sec.
Rear Defogger Timer
1. Time specification
T1 : 0.1 sec.
T2 : 15 ± 3min.
Seat Belt Warning
1. Time specification
T1 : 6 sec. ± 1 sec.
T2 : 6 sec. ± 1 sec. MAX.
T3, T4 : 0.3 sec. ± 0.1 sec
Door Warning
1. Time specification
T1, T2 : 0.3 sec. ± 0.1 sec.
Central Door Lock/Unlock
1. Time specification
T1 :0.5 sec. ± 0.1 sec.
Ignition Key Reminder
1. Time specification
T1 T3 : 0.5 sec.
T2 : 1 sec.
T4 : 0.5 sec. MAX.