Heated Glass Control Module: Testing and Inspection
Central Control ModuleOperation Check of Components
While operating the components, check whether the operations are normal with timing chart.
1. Variable intermittent wiper
Time specification
T1 : Max. 0.7 sec.
T2 : Time of wiper motor 1 rotation.
T3: 1.5 ± 0.7 sec. (VR=0kOhms) - 10.5 ± 3 sec. (VR=50 k ohms)
2. Washer
1. Time specification
T1 : 0.6 sec
T2 : 2.5 - 3.8 sec
2. This function should be operated preferentially even though the variable intermittent wiper is operating.
3. Rear window defogger
Time specification
T1: 20 ± 3 Min.
4. Seat belt warning
Time specification
T1,T2: 6 ± 1 sec.
T3: 0.3 ± 0.1 sec.
5. Ignition key hole illumination
Time specification
T1: 10 ± 2sec.
T2: 0 - 10 sec.
6. Delayed out room lamp
Time specification
T1 : 2 ± 0.5 sec.
T2 : 4 ± 1 sec.
T3 : 0 - 6 sec.
7. Door warning
Time specification
T1,T2 : 0.3 ± 0.1 sec.
8. Ignition key reminder
Time specification
T1 : 5.0 sec.
9. Door key illumination
1. Time specification
T1 : 10 sec.
10. Power window timer
Time specification
T1 : 30 ± 5 sec.