Main Relay (Computer/Fuel System): Testing and Inspection

When the ignition switch is on, battery power is supplied to the ECM, the injectors, the mass air flow sensor, etc. While the ignition switch is turned on, current flows from the ignition switch through the current relay coil to ground.

Circuit Diagram:






Harness Inspection Procedure (Step 1 - 2):






MFI CONTROL RELAY INSPECTION










1. Check continuity of relay contacts between terminals 4 (+) and 2 (-).
2. If faulty, replace the MFI control relay.

Tightening torque

MFI control relay: 7 - 11 Nm (70 - 110 kg.cm, 5.2 - 8.1 lb.ft)