Operation CHARM: Car repair manuals for everyone.

Vehicle Speed Sensor: Testing and Inspection

ACTUATOR INSPECTION

RESISTANCE MEASUREMENT BETWEEN TERMINALS
1. Disconnect the connector at the idle speed control actuator.
2. Measure the resistance between terminals.

Standard value
Terminal 1 and 2: 10.5 - 14 Ohms
Terminal 2 and 3: 10 - 12.5 Ohms at 20 °C (68 °F)

3. Connect the connector to the idle speed control actuator.