Operation CHARM: Car repair manuals for everyone.

Antitheft and Alarm Systems: Testing and Inspection

ANTI-THEFT FUNCTION




1. Arm function
Time specification
T1 : 0.5 sec
T2 : 0.5 ± 0.1sec.
T3: Max 2sec.

2. Disarm function




1. In case of using the door key




2. In case of using the transmitter (TX) unlock button
Time specification
T1: 0.5 ± 0.1 sec.
T2: 1 ± 0.1 sec.

3. Alarm function




1. Time specification
T1: 27 sec.
T2: 10 sec
T3: 0.5 ± 0.1 sec.




2. Battery is separated during the alarm state




3. New alarm occurs during the alarm state




4. Disarmed with door key during the alarm state




5. Disarmed with TX(Transmitter) during the alarm state




6. TX lock button pressed when the door opened during the alarm state




7. Trunk is unlocked during the alarm state





4. Alarm holding function

5. Coding saving method.
1. Remove the center facia panel.





2. Code saving: Activating the keyless entry-receiver unit and change code saving switch of the receiver unit from "OFF" to "SET".

The secret codes from the transmitter are stored into the receiver unit when the door lock button or unlock button pressed.

Code change : Change code saving switch of the receiver unit from "OFF" to "SET".

The same secret code from transmitter are stored info the receiver unit when the door lock or unlock button from the changing transmitter are pressed.
The code saving of 2nd transmitter unit will be achieved in the same method.

3. Install the center facia panel.