Turn Signals: Description and Operation
With the hazard switch in
OFF and ignition switch in
ON or START, battery voltage is applied from fuse 9 to the flasher unit. The solid-state in the flasher unit senses the turn switch signal and then through the coil control alternately supplies and removes battery voltage to the
turn signal switch. Voltage is applied to the left or right
turn signal lamp and indicators dependent upon the turn switch position.