Operation CHARM: Car repair manuals for everyone.

Ambient Temperature Sensor / Switch HVAC: Testing and Inspection

Ambient Temperature Sensor




CHECKING
1. Disconnect battery terminal (-).
2. Detach the harness of the ambient temperature sensor.
3. Measure the resistance as shown.

Resistance 20 °C.........36.5 ± 2.3 kohm