Magnetic Switch Hold-In Test
MAGNETIC SWITCH HOLD-IN TEST1. Disconnect the field coil wire from the M-terminal of the magnetic switch.
2. Connect a 12 V battery between the S-terminal and the body.
NOTE: This test must be performed quickly (in less than 10 seconds) to prevent the coil from burning.