Magnetic Switch Pull-In Test
MAGNETIC SWITCH PULL-IN TESTFig. 5 Starter Motor Testing:
1. Disconnect the field coil wire from the M-terminal of the magnetic switch.
2. Connect a 12 V battery between the S-terminal and the M-terminal.
NOTE: This test must be performed quickly (in less than 10 seconds) to prevent the coil from burning.
3. If the pinion moves out, then the pull-in coil is good. If it doesn't, replace the magnetic switch.