Operation CHARM: Car repair manuals for everyone.

Electrical Specifications

Type MF 68 AH

Ampere hours
5HR 54 AH
Cold cranking [at -18 °C (0 °F)] 600 AH
Reverse capacity 110 min.
Specific gravity [at 25 °C (77 °F)] 1.280 ± 0.01

NOTE: COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2 or greater at a specified temperature. REVERSE CAPACITY RATING is the amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5 at 26.7 °C (80 °F).