W/Harness Inspection
Terminal and Connector Inspection
1. Many malfunctions in the electrical system are caused by poor harness and terminals.
Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2. Thoroughly check shorting connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3. Has a problem been found ?
Telltale lamp Circuit Inspection
1. Ignition "OFF".
2. Disconnect SRSCM main harness connector.
3. Ignition "ON" & Engine "OFF".
4. Measure voltage between terminal "23" of the SRSCM main harness connector and chassis ground.
Specification : Batt Voltage
5. Is the measured voltage within specifications ?