W/Harness Inspection
Electronic Control Suspension
C2302 Air Spring Valve-FL Open/Short - W/Harness Inspection
Terminal and Connector Inspection
1. Many malfunctions in the electrical system are caused by poor harness(es) and terminal condition.
Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3. Has a problem been found?
Power Circuit Inspection
Check for open in harness
1. IG "OFF"
2. Disconnect solenoid valve ASSY connector and ECS ECU connector.
3. Measure resistance between power terminal of the solenoid valve ASSY harness connector and power terminal of the ECS ECU harness connector.
Specification : Below approx. 1 Ohms
4. Is the measured value within specification?
Check for short in harness
1. IG "OFF"
2. Disconnect solenoid valve ASSY connector and ECS ECU connector.
3. Measure resistance between power terminal of the solenoid valve ASSY harness connector and chassis ground.
Specification : Infinite
4. Is the measured value within specification?
Control Circuit Inspection
Check for open in harness
1. IG "OFF"
2. Disconnect solenoid valve ASSY connector and ECS ECU connector.
3. Measure resistance between control terminal of the solenoid valve ASSY harness connector and control terminal of the ECS ECU harness connector.
Specification : Below approx. 1 Ohms
4. Is the measured value within specification?
Check for short in harness
1. IG "OFF"
2. Disconnect solenoid valve ASSY connector and ECS ECU connector.
3. Measure resistance between control terminal of the solenoid valve ASSY harness connector and chassis ground.
Specification : Infinite
4. Is the measured value within specification?