Scantool Diagnostics
Smart Key Unit (Button)
P1696 Immobilizer-Authentication Fail - Scantool Diagnostics
Monitor Scantool Data
1. IG KEY "ON" & Engine "OFF".
2. Erase DTC after connecting Scantool.
3. Check IPM status if DTC is retrieved.
Fig.1) It shows that 2 (two) FOB key is registered, Smart Key ECM (integerated in IPM) is learnt status.
4. Is the Smart key ECM (Integrated in IPM) learnt status?