Scantool Diagnostics
Head Unit
U1501 Wakeup Line Short Circuit To Vcc - Scantool Diagnostics
Monitor Scantool Data
1. Connect scantool to Data Link Connector (DLC).
2. IG "ON" & Engine "OFF".
3. Select "Ring break diagnosis "in Inspection / Test option and monitor "Test results".
4. Checking the component status by "Wake up line diagnosis".
Fig.1) Ring break diagnosis
Fig.2) Ring break diagnosis between TV Tuner and Head Unit
Fig.3) Start of X dB Test
Fig.4) Result of X dB Test
Fig.5) Test of Wake up line diagnosis
Fig.6) Result of Wake up line test
5. Has a problem been found at wake up line?
Wake up line short circuit to ground inspection
Check wake up line short circuit to ground
1. IG "ON" & ENG "ON".
2. Connect scantool to Data Link Connector (DLC) and select oscilloscope option.
3. Start "Wake up line diagnosis" and measure waveform each wake up line.
4. Disconnected all connect of components and check the status of each wake up line of chassis ground.
Specification : If measured waveform is within specification, its normal.
If measured voltage is "0", Its normal.
5. Has a problem been found at wake up line?