Memory Positioning Systems: Description and Operation
Description
The Tilt & Telescope operation function in SCM contains of the following function.
1. Manual control with direction switches (Tilt Up/Down, Telescope Forward/Backward).
2. Playback with position switches (P1 and P2 switches).
3. Memory with position switches (P1 and P2 switches).
4. Easy Access operation control according to the IGN SW SCM = Key Off->Key Off exception or IGN SW SCM=Key Off exception -> Key Off
5. Easy Entry Position Renewal
6. Arbitration control
7. Detecting error
8. Notice (Manual, Memory Playback, Easy Access operation)
Operation
Behavior For Normal State
Manual Control With Direction Switches
1. Tilt & Telescope operation is carried out in SCM according to user handling of direction switches when the following conditions are satisfied.
A. Only one of direction switches is pressed ON (Tilt Up/Down , Telescope Forward/Backward).
2. SCM is different from a value of maximum continuous time for each motor
A. Tilt : 6s +/- 1s
B. Telescope : 6s +/- 1s
3. Manual has priority although self-diagnosis actuator operation order is received (actuator operation ignorance)
Soft Limit Setting By Manual Switches
1. The basis value must be set 8000H and both direction SOFT LIMIT must be open at the first time at B+ condition
2. The LIMIT must be renewal in all range by MANUAL operation at the first setting of LIMIT
3. If the error is occurred during operation, after saving the ERROR DATA in EEPROM, easy access position is deleted and only SOFT LIMIT to going direction is deleted.
4. The LIMIT must be reset in all range and in easy access (get out) after recovery form error.
5. The SOFT LIMIT is presented ±12PULSE from mechanical limit position
Mechanical Limit Setting By Normal Operation (TILT)
1. The initial SOFT LIMIT is set 8000H (It can't work as SOFT LIMIT)
2. The mechanical LIMIT is renewal by MANUAL SW of TILT to up or down.
3. If 4 pulse is not occurred in 1 sec. in running to up or down direction at the first time, the mechanical LIMIT is set.
4. In case of the difference of both limit pulse is over 100pulse, SOFT LIMIT is set at ±12PULSE from Mechanical limit.
Mechanical Limit Setting By Normal Operation (TELE)
1. The initial SOFT LIMIT is set 8000H (It can't work as SOFT LIMIT)
2. The mechanical LIMIT is renewal by MANUAL SW of TELE to push direction or pull direction.
3. If 4 pulse is not occurred in 1 sec. in running to push direction or pull direction at the first time, the mechanical LIMIT is set.
4. In case of the difference of both limit pulse is over 120pulse, SOFT LIMIT is set at ±12PULSE from Mechanical limit.
Memory With Position Switches
When no manual operation is performing,
- SCM memorizes position once if one of Mem P1 CMD or Mem P2 CMD command is changed to ON.
1. Memory enable
A. CAN signal Mem ENB=Enable
2. Memory operation
A. If CAN signal Mem P1 CMD=P1 or Mem P2 CMD=P2 is received, SCM memorize a present Tilt & Telescope position
3. The notice about memory
A. Memory must not be clear even though battery is removed.
Easy Access Operation
The Easy Access operation function controls Tilt & Telescope position according to IGN SW SCM = Key Off exception->Key Off or Key Off->Key Off exception.
If IGN SW SCM = Key Off exception is changed to IGN SW SCM = Key Off, Tilt and Telescope move to the maximum up SOFT LIMIT and PUSH SOFT LIMIT direction.
And if IGN SW SCM = Key Off is changed to IGN SW SCM = Key Off exception, Tilt and Telescope move to a position that IGN SW SCM = Key Off exception -> Key Off was occurred
Arbitration Control
Tilt & Telescope function is carried out according to the following priority table. If Tilt & Telescope requirement happen same time.
* "-" : Non-existence condition